*" Ver" represents the version of the program.
Item
Gyro type
Excitation frequency
Rotor voltage
Stator voltage
Ratio
Supply voltage
NMEA output
Self-test (Enable)
AD format data
transmission interval
Power-off function*
Detection of "Stator"
disconnection
Note:
When the GC board of the Ver-05 is incorporated in RPU-013, and the power-off function is set to
"Enable" and when power-off is detected, all the output data are stopped. When this happens, set
the HDG value in the [HDG] box menu again.
How to Check the Program Number
A label showing the specification is attached onto U1 of the GC board. You can
check the program number from the suffix of the marking.
U1
64S4097-0
64S4097-1
64S4097-2
Factory setting
AC synchro
50/60 Hz
60 VAC to 135 VAC
60 VAC to 135 VAC
360x
30 VAC to 135 VAC
40 VDC to 100 VDC
- NMEA Ver : 1.5
- Baud rate
: 4800 bps
- Talker name* : AG (Ver-03, 04)
: HE (Ver-05)
- Interval
: 1 second
- Sentence : HDT+VHW
Do not do self test (Disable)
→ 25 ms
- J7, 8, 9
- J10, 11, 12 → 200 ms
Ver-05
AD-100: Enable
GC: Disable
Enable (Ver-03, 04)
(AD data is not output when the
disconnection of "Stator" is detected.
the only 25 ms AD format data .)
Enable (Ver-05)
(When the disconnection of "Stator"
is detected, all AD output data are
stopped.)
Program Ver
Ver-03
Ver-04
Ver-05
4-43
4.7 Setting of AD-100 or GC-10
Table 4.7.2 Overview of Factory Setting
Recommended setting
Make the setting according
to the connected gyro.
When NMEA is used,
- NMEA Ver-2.0
- 38,400 bps
- Output
interval 25 ms
Set whichever desired
This function is not
available for Ver-03 and 04.
Use at "25 ms"
Set as "Disable"
Set as "Enable"