MM-ADP Cabling
One 11 pair cable from the High Performance Administrative Processor Unit
(HPU) of the Central Module which connects both copies of AP to the ADP is
laid. This cable placement detail is given in Chapter 10, Section 10.6.3. For
terminations at the ADP end, a 25 pin D-Type female connector is used and
at the HPU end it is two 7/2 IDC connector (enclosed in a hood).
For -48V DC supply, a 4 core single cable is connected from IOP PDP through
an MCB of 2A to the rear panel of ADP. 2 Cores of this cable are used for -
48V and 2 cores for ground. Cable details are given in Chapter 10, Section
10.5.24 on cable laying. Use Red and Yellow/Green core for ground and Blue
and Yellow for -48V.