C-DOT DSS MAX-XL Installation Manual page 353

Table of Contents

Advertisement

18.6.2.
Memory Diagnostics
Set up
18.6.3.
Clock Diagnostics
Same as in 18.6.1
Set up
1.
2.
3.
4.
5.
6.
7.
18.6.4.
CMS Diagnostics
Set up
Same as in 18.6.1
1.
INSTALLATION MANUAL
IOP-0 is INS-ACT
AM, CM completely initialised and all units are inservice.
1.
Make SSC-0 INS-ACT, SSC-1 INS-SBY
2.
Make MU-0 OOS-OPR, MU-1 INS-ACT
3.
Give command DGN-SWU for MU-0. If memory does If
diagnostics are okayed then bring MU-0 inservice by PUT-SWU-
INS command. If diagnostics are failed take appropriate action.
4.
Make MU-1 OOS-OPR, MU-0, INS-ACT
5.
Repeat step 3 for MU-1
6.
Interchange SSC
7.
Repeat steps 2 to 6 with SSC-1 active.
Make SSC-0 INS-ACT SSC-1 INS-SBY
Make CLK-0 OOS-OPR, CLK-1 INS-ACT
Give command PUT-SWU-INS for CLK-0, if clock card does not come
up then run diagnostics on CLK-0 and take appropriate action. Run
diagnostics again if diagnostics are okayed then bring CLK-0 inservice
by put-swu-ins command.
Make CLK-1 OOS-OPR, CLK-0 INS-ACT
Repeat step 3 for CLK-1
Interchange SSC
Repeat steps 2 to 6 with SSC-1 active.
Make SSC-0 INS-ACT, SSC-1 INS-SBY
FUNCTIONAL TESTING
353

Advertisement

Table of Contents
loading

Related Products for C-DOT DSS MAX-XL

Table of Contents