Chapter 10.
10.6.11.
Digital Cable For RSU
For each RSU, eight digital Trunk cables (4 for bus-0 and 4 for bus-1) are
required on CM-XL side and cables in each bus are tied together as shown in
Fig. 10.47 (a) and 10.47 (b). These cables are required only when RSUs are to
be parented to MAX-XL.
10.6.11.1.
Detail of Digital Trunk Cable (For RSU Link)
C-DOT ASSY NO.
DRAWING NO.
CABLE PART NO.
CABLE MARKER NO.
CABLE DESCRIPTION
CABLE UNIT COLOR CODE
CABLE LENGTH
SOURCE TERMINATION PART NO.
DESTINATION TERMINATION PART
NO.
SOURCE PLACEMENT
TAB NO. RETAINED
DESTINATION PLACEMENT
ASSEMBLY PROCEDURE
230
:
ACB-MAXRMDXX-000
:
Fig. 10.47 (a) & 10.47 (b)
:
MCA-PVCTPS04-401 MCA-PVCSC013-401
:
M`N' `uu', M`N' `vv',
M`N' `xx', M`N' `yy'
Where N =
A for Bus 0
B for Bus 1
Refer Table No. 10.25 for uu, vv, xx, yy.
:
Shielded digital cable 4 pairs.
32/0.2mm black colour PVC wire.
:
GREY.
:
* Digital cable - 4x25 m. excluding unsheathed
section
# Ground cable - 0.3 m
:
Wire Wrap Contact block.
MCC-BCFSW307-002
Polarised Hood 14 contact Module.
MCC-BPPOH207-401
:
Digital cables - stripped wire to MDF
# Ring Terminal 2.5sq. mm/M6.
MCT-ERRIN015-401
# 32/0.2 mm. PVC wire, black
(MCA-PVCSC013-401) 0.3m in length
:
Frame - BTU 0/1 in CM-XL.
Slot - ESM slot
Connector - B
:
TAB NO. -
1 For Module1
2 For Module 2
:
MDF
Refer fig. 10.47 (a) & 10.47 (b) and table 10.25
& 10.26.
:
Wire Wrapping
C-DOT DSS MAX-XL