Set up
18.9. SSU TESTING
Set up
INSTALLATION MANUAL
CM is fully initialised and BM-CM cables are connected.
1.
Make SSC-0 INS-ACT, SSC-1 INS-SBY.
2.
Make IFC1 OOS-OPR.
3.
Give command DGN-SWU for IFC1. If diagnostics are okayed
then bring the PSM card inservice by PUT-SWU-INS command.
If diagnostics are failed, take appropriate action.
4.
Repeat step and 2 and 3 for all other PSM (IFC) cards which are
equipped.
5.
Interchange SSC
6.
Repeat step 2 to 4 for all IFC cards with SSC-1 active.
CM is fully initialised and BM-CM cables are connected
1.
Make SSC-0 INS-ACT, SSC-1 INS-SBY.
2.
Make the SS-0 (Switch Plane ) OOS-OPR, SS-1 should be INS-
ACT
3.
Give command PUT-SWU-INS for Switch Plane SS-0. If
diagnostics are okayed then bring the SS-0 inservice by PUT-
SWU-INS command. If diagnostics are failed, then take
appropriate action by changing the failed card in DGN report.
SS-0 i.e. switch plane 0 means (SSBID-0, CLK-0 all SWCs-0)
and SS-1 means (SSBID-1, CLK-1, SS-1 all SWCs-1). (NSC is
part of CLK).
4.
Repeat step 2 & 3 for SS-1
5.
Interchange SSC
6.
Repeat step 2 to 4 with SSC-1 active.
FUNCTIONAL TESTING