Appendix-Ibm Equipage Procedure - C-DOT DSS MAX-XL Installation Manual

Table of Contents

Advertisement

BM Equipage Procedure
This Appendix explains the procedure for equipping a Base Module in MAX-XL.
Please follow the procedure in this sequence.
Note
For expansion of existing exchanges, please refer to C-DOT DSS MAX-XL exchange
operation Document.
PROCEDURE TO EQUIP A BM :
1.
Take the one IOP [say IOP-0] to Warm start level using init-iop command.
2.
IOPXX) cd /u/admn/cmdfile
3.
Invoke utility conv_cmd with physical bm no. in a command line parameter
e.g. to equip BM No. 5 give :
IOPxx ) sh conv_cmd l
The following are the input parameters.
Configuration
BM Number [1 to 32]
Normal/Remote [N/R]
4.
Invoke crp
5.
Execute the following crp commands at crp prompt.
< exec-cmd-file:aemod.cmdo;
< exec-cmd-file:aefrm.cmdo;
< exec-cmd-file:amslm.cmdo;
< exec-cmd-file:aesrv.cmdo;
< exec-cmd-file:amtam.cmdo;
< exec-cmd-file:aemfc.cmdo;
371
C-DOT DSS MAX-XL
Appendix - I
:
xl
:
5
:
N