Alarm Testing - C-DOT DSS MAX-XL Installation Manual

Table of Contents

Advertisement

2.
3.
4.
5.
6.

18.14. ALARM TESTING

18.14.1.
HPU Alarm Test
Set up
18.14.2.
SCU Alarm Test
Set up
1.
2.
INSTALLATION MANUAL
Make BUS-1 OOS-OPR for BM1 and BM3 i.e. IFC17 and IFC-18
should be OOS-OPR. Now make inter BM calls, calls should be
successful and check speech. Bring IFC17 & IFC18 inservice.
Make BUS-0 OOS-OPR for BM1 and BM3 i.e. IFC1 and IFC2 should
be OOS-OPR. Now make inter BM calls, calls should be successful and
check speech. Bring IFC1 and IFC2 inservice.
Make BUS-0 OOS-OPR for BM1 and BUS-1 OOS-OPR for BM3 i.e.
IFC1 and IFC18 should be OOS-OPR. Now make inter BM calls, calls
should be successful and check speech. Bring IFC1 and IFC18
inservice.
Make BUS-1 OOS-OPR for BM1 and bus-0 OOS-OPR for BM3 i.e.
IFC2 and IFC17 should be OOS-OPR. Now make inter BM calls, calls
should be successful and check speech. Bring IFC2 and IFC17
inservice.
Make inter BM calls in all BMs and check voice path.
A full duplex system
1.
Switch off one power supply of plane 0 of HPU, alarm should
come on ADP and OOD indicating plane 0 power supply faulty
in HPU. Check status of all units in AM and CMSs. They all
should be inservice.
2.
Switch on the PSU for AP-0 plane, alarm for PSU of HPU should
be cleared.
3.
Repeat steps 1 and 2 for all other PSUs in HPU taking one at a
time.
A full duplex system
Make SSC-0, MU-0, SSBID-0, CLK-0, OOS-OPR, but SSC-1, MU-1,
SSBID-1, CLK-1 should be INS-ACT.
Switch off PSU (in slot 3) of plane 0 of SCU. No alarm.
FUNCTIONAL TESTING
363