Chapter 10.
10.5.16.
Details of –48V GND Cables from IOP PDP to IOP PDP FBI Card
CDOT ASSY NO.
DRAWING NO.
CABLE PART NO.
CABLE MARKER NO.
CABLE SPECIFICATION
CABLE UNIT COLOUR CODE
CABLE LENGTH
SOURCE TERMINATION PART NO.
DESTINATION TERMINATION NO.
SOURCE
DESTINATION
ASSEMBLY PROCEDURE
Refer Fig. 10.7 (e) for block diagram.
170
:
ACB-MAXLPGVX-000
:
FIG. 10.23
:
MCA-PVCSCP03-401
:
PGV1 (-48V GND copy 0)
PGV2 (-48V GND copy 1)
:
2.52 PVC insulated Cable
:
Red
:
85 cm
:
MCC-ERRIN102-401
(Ring terminal 2.5 mm
:
MCC-FASTP001-401
Faston Receptacle
MCC-FASTP002-401
Insulating Boot
:
-48V Gnd busbar of IOP-PDP
:
FBI Card J37 (PGV1)
FBI Card J39 (PGV2)
:
Crimping tool SYT-2
crimp type)