Manage Automation

You use automation to control playback, the projector, and external devices. The Christie IMB
includes built-in support for some external automation devices. If the device is not supported, you
can use the serial-over-Ethernet protocol to send automation commands.
This section provides instructions for managing and defining:
Macros - A macro is a list of actions that you define. For example, opening the curtains or
turning on the house lights at the end of playback. A macro can be activated by a global trigger,
or it can be added to a play list.
Input Cues - Input cues wait for events such as a general purpose input (GPI) state change or
an Ethernet message received on TPC port 5111. An input cue in a play list delays playback until
an event occurs. In a global trigger, a macro runs when an input cue event occurs. These are the
available input cues:
Automation Device
Projector
IMB Automation
IMB Automation
Global Triggers - A global trigger combines an input cue with a macro. When the predefined
event for the input cue occurs, the output macro is triggered. For example, a fire alarm input
signal could cause playback to stop and the house lights to come on. A global trigger is always
active and is not dependent on specific play list definitions.
To add a macro or an input cue to a play list, see
Christie Integrated Media Block User Manual
020-100845-05 Rev. 1 (08-2013)
Action
Lamp Off Event
An event starts when the lamp turns off.
Serial String Input
Waits for a serial string.
GPI Wait
Waits for a GPI event. Not available on
Solaria One or Solaria One
Add Automation to a Play List
Description
+
.
on page
72.