Control Christie Act Automation; Control Integ Jnior Automation - Christie IMB User Manual

Integrated media block
Table of Contents

Advertisement

4. Select a device.
5. Tap Accept.
6. Enter a name for the device and then tap Enter.
7. Complete the Name, IP Address, Username, Password, and Serial Command Port fields.
8. Tap Save.

Control Christie ACT Automation

These are the available built-in commands for the Christie ACT:
Command
ACT Ethernet cue
Buzzer
Button
Pulse relay
Open/Close relay
GPO pulse
GPO set all
Run script
Flash LED
Set all LEDs

Control INTEG JNIOR Automation

Christie recommends that you use the built-in commands to control an INTEG JNIOR device. These
are the available built-in commands:
Command
Open relay
Close relay
Pulse relay for x ms
Execute macro x
You can create macros on the JNIOR device and call them using the Execute Macro command.
To create and run macros on the JNIOR, use the JNIOR Support Tool to enable and configure the
Cinema.JNIOR application. It is recommended that you install Cinema.JNIOR version 2.22.1115.1501
or later. For additional information, see INTEG Process Group (www.integpg.com).
The default Ethernet port for sending automation commands to the JNIOR is port 9200.
Christie Integrated Media Block User Manual
020-100845-05 Rev. 1 (08-2013)
Description
Sends a string to the ACT Ethernet input cue.
Activates the buzzer for the specified time (in milliseconds).
Simulates pressing or holding the ACT button.
Sends a pulse to a specific relay.
Opens or closes a specific relay.
Sends a pulse to a specific GPO pin.
Sets the values for all GPO pins.
Runs a script on the Christie ACT.
Causes a specific LED to flash.
Sets values for all of the LEDs.
Description
Opens a specific JNIOR relay.
Closes a specific JNIOR relay.
Sends a pulse to a specific JNIOR relay for the specified time
(in milliseconds).
Executes a JNIOR macro.
Manage Automation
39

Advertisement

Table of Contents
loading

Table of Contents