Automation Type
Dolby CP750 volume at 5.0
Douser Open
Add Activities to the Trailers and Feature Macro
You cannot add GPO activities to Solaria One and Solaria One
communication panel does not include a GPI/O port.
1. Tap the Trailers and Features macro in the left pane.
2. Tap Add in the Macro Activities list.
3. Select IMB Automation in the Automation Device list.
4. Select GPO Set in the Activity Type list.
5. Select 4 in the Pin Number list.
6. Select Low in the Signal Direction list.
7. Tap Accept.
8. The new activity is added to the Macro Activities list.
9. Tap Save.
10. Repeat steps 2 to 9 and add this activity:
Automation Type
Lights 50% (GPO 4 High, GPO 5 Low)
Christie Integrated Media Block User Manual
020-100845-05 Rev. 1 (08-2013)
Field Settings
Automation Device: IMB Automation
Activity Type: Serial String Output
Serial String: cp750.sys.fader 50\0D
IP Address: 192.168.1.20
Port: 61408
Automation Device: Projector
Activity Type: Projector
Action: Douser Open
Field Settings
Automation Device: IMB Automation
Activity Type: GPO Set
PIN Number: 5
Signal Direction: Low
Manage Automation
+