F3 COMPACT Service Manual
_______________________________________________________________________________________________________________________
12
4308-0019
13
31-03512-980
14
4005-0095
15
8001-0020
16
8005-0071
3.7.1 Replacing the Armrest
a.
To replace the armrest:
Prepare a clean well lit workspace.
•
Turn the detector off and remove the batteries.
•
Remove the four (4) screws from the top of the armrest and remove the armrest. Figure
•
87.
b.
The armrest can now be replaced as an assembly. If the armrest slide assembly must also
be replaced then the detector body must be opened as described in Section
Detector
Body.
Reattach the armrest and fit the four (4) screws (12mm)
•
Check the armrest folds in and out correctly and also check that the armrest slides
•
backward and forward.
Pin Long Armrest
Screw M3.5x12 skt head
Bush Friction Armrest
Armrest Flap Lower Right
Armstrap with Buckle
Table 6. Armrest Kit with Slide
Figure 87: Removing the Armrest
54
Armrest Slide
3.1 - Opening the