b.
Open the detector body as described in Section
completed:
Remove the four (4) screws (12mm) from the speaker assembly in the right side of the
detector body. Figure 96.
Check speaker assembly is in good working order and the speaker cable is correctly
sealed into the speaker assembly and the circlip is installed.
Check the speaker O-ring is clean, lightly greased and correctly positioned in its channel in
the detector body.
Position the speaker assembly and insert the four (4) screws (12mm).
c.
Assemble the detector as described in Section
E-Clip
Figure 96: Replacing Speaker Assembly
3.1 - Opening the Detector
3.2 - Closing the Detector
63