Fit the bracket main PCB.
Check that three (3) jumpers are connected in the correct positions on the main PCB.
Refer to Figure 39.
Figure 39: Three (3) Jumpers on Main PCB.
b.
The main PCB is now ready to install into the F3 COMPACT.

3.3.3 Installing the Main PCB.

Having opened the detector body and removed the faulty main PCB, install a serviceable
a.
main PCB as follows:
Place the detector on its left side in a clean well lit area.
Lower the main PCB into the detector, pushing the bottom side (away from the handle)
down and into place first. Gently position the main PCB flat inside the detector. Figure
40.
Gently slide the main PCB rearward towards the battery compartment so that the ends of
the main PCB insert into the locating slots in the detector body.
Figure 38: Fitting Bracket
29
F3 COMPACT Service Manual
10 Way Ribbon Cable.
Bracket Main PCB.