3.3.1 Removing the Main PCB

a.
To remove the main PCB, open the detector body as described in section
Detector Body
and:
Remove the Nut (18mm) from the coil connector. Figure 32.
Unscrew the screw toroid from the main PCB, using a 2.5mm hex key driver. Figure 33.
Disconnect the battery connector from the main PCB.
Remove the two (2) Screws (12mm) from the interface PCB. Figure 34.
Figure 31: Opened Detector Body
Figure 32: Removing the Coil Connector Nut (18mm)
Figure 33: Screw Toroid & Battery Connector
Screw Toroid
Battery Connector