Minelab F3 COMPACT Service Manual page 16

Metal mine detector
Hide thumbs Also See for F3 COMPACT:
Table of Contents

Advertisement

F3 COMPACT Service Manual
_______________________________________________________________________________________________________________________
Figure 11: Disconnecting Coil Plug and Removing Screws
Turn the detector over onto its left side with speaker grill uppermost.
Using the 3mm hex key driver (3mm Allen Key) remove all 8 screws from the detector
body. Figure 12.
There are four (4) x 35mm long screws and four (4) x 20mm long screws.
Using a T20 Torx (star) driver unscrew all four (4) screws (3 x 35mm and 1 x 20mm) from
the right side of the detector. Figure 13.
NOTE
Figure 12: Removing 8 Screws.
Figure 13: Removing four (4) Torx Screws
16