Lay the cable 10 way under the interface PCB. Take note of the connector key tab that
aligns with the slot in the interface PCB. Figure 43.
Gently align and connect the connector 10 way. Figure 43.
Align the cable 6 way ribbon with its connector. Slide the connector locking bail outwards
to accept the cable 6 way ribbon. Figure 44.
Insert the cable 6 way ribbon into the connector then push the locking bail in to secure.
1. Pull locking bail out to accept Cable
2. Insert 6 Way Ribbon Cable
Connect the battery connector to the main PCB. Figure 45.
Figure 43: Connector 10 Way
Figure 44: Connecting Six Way Ribbon Cable
Figure 45: Connecting Battery Connector
31
F3 COMPACT Service Manual
Alignment Key
3. Push locking bail