Post-Dive Checks - Teledyne SeaBat T Series Operator's Manual

Deep/shallow high-resolution multibeam sonar system
Hide thumbs Also See for SeaBat T Series:
Table of Contents

Advertisement

SYSTEM STARTUP AND SHUTDOWN
2.
Select the Shutdown option in the Application Settings dialog to shut down the sonar
system.
3.
Click OK.
This will terminate the connection to the SSP/sonar system from laptop/PC.
4.
Click the cross in the upper right corner of the Sonar UI to terminate the session.
The Sonar UI will reload the same selection of sonar settings, once the system is
started again.
5.
To shut down the laptop/PC, press the power button (or follow Windows procedure).
3.5

Post-dive Checks

Once the SeaBat T-Series Subsea system is recovered to deck, perform the following checks.
1.
Shut off all power to the SeaBat T-Series Subsea system.
2.
Using fresh water, wash down all system components to minimize salt accumulation
and the development of localized corrosion pits.
Do not use hot or cold pressure washers. The high-velocity water spray will cut
through the polyurethane or damage the interface between the polyurethane and
the metal housings.
3.
If necessary, schedule troubleshooting and/or repair of the suspected unit.
4.
Inspect all cables for signs of twisting or abrasion.
5.
Inspect the cables, transducer arrays, and SSP for any signs of damage or oil
leakage.
SeaBat T-Series Subsea Operator's Manual
Version 7
CAUTION
Page 14
January 31, 2019