TROUBLESHOOTING
Message
RDR Record failed - Set file name failed:
<x>
Roll Compensation is not available.
Roll Compensation is not available.
Subscriber send() failed
Subscriber UDP sendto() failed
Subscribers outbound MMF buffer memory
overwrite error!
Subscribers outbound MMF buffer read
error!
TCP interface status: Down
TCP Server - Unknown packet type
TCP Server - Warning max connections
reached
Trigger out length (x) is invalid
SeaBat T-Series Subsea Operator's Manual
Version 7
Description
The hard drive is getting full. One or
more errors have occurred in
conjunction with data recording.
The input data for motion is not
available or the feature is not enabled.
The input data for motion is not
available or the feature is not enabled.
The software was unable to send data
to a connected client.
The software was unable to send data
to a connected client.
The link to the user interface running on
the sonar processor has detected a
non-critical error.
The link to the user interface running on
the sonar processor has detected a
non-critical error.
One or more PCI bus or network
resources has failed to initialize.
A connected client has sent an
unrecognized command to the
software.
The network module has become
saturated with client connections and
will refuse any further connections.
An unsupported value was received for
trigger setup.
Page 92
Action
Check user permissions and available
disk space. Check file names and
recording directories
Check device inputs and cabling.
Check device inputs and cabling.
Check network resources and user
permissions.
Check network resources and user
permissions.
Check system resources, shutdown all
non-critical software applications.
Reboot processor.
Check system resources, shutdown all
non-critical software applications.
Reboot processor.
Check user permissions and sonar
processor network hardware.
Review client software source code or
definitions for correct implementation of
Teledyne RESON 7k Data Format.
Close some of the connected clients.
Check settings in user interface.
Type
Data Recording
Input Signal
Input Signal
Data Subscription
Data Subscription
Data Subscription
Data Subscription
Startup
Network
Components
Network
Components
External Trigger
January 31, 2019