TROUBLESHOOTING
Message
Non Sonar Data FIFO overflow (x packet)
PCI interface status: Down
PING <x> :( Lost FPGA sync...sample
PING <x> :( Lost FPGA sync...sample
Roll Compensation is not available.
Pitch Compensation is not available.
RDR - <x> already in progress.
RDR - Already in Playback/Record mode.
RDR - Data <x> failed to stop.
SeaBat T-Series Subsea Operator's Manual
Version 7
Description
An error has occurred in reading of
BITE data. The data buffer has
overflowed.
One or more PCI bus or network
resources have failed to initialize.
One or more pings have been lost due
to an error on the uplink between the
receiver and the software. The system
is becoming unstable and data transfer
is corrupted on the PCI bus.
One or more pings have been lost due
to an error on the uplink between the
receiver and the software. The system
is becoming unstable and data transfer
is corrupted on the PCI bus.
The input data for motion is not
available or the feature is not enabled.
The input data for motion is not
available or the feature is not enabled.
The hard drive is getting full. One or
more errors have occurred in
conjunction with data recording.
The hard drive is getting full. One or
more errors have occurred in
conjunction with data recording.
The hard drive is getting full. One or
more errors have occurred in
conjunction with data recording.
Page 90
Action
No action needed.
Check user permissions and sonar
processor network hardware.
Reboot. Check sonar processor
hardware.
Reboot. Check sonar processor
hardware.
Check device inputs and cabling.
Check device inputs and cabling.
Check user permissions and available
disk space. Check file names and
recording directories
Check user permissions and available
disk space. Check file names and
recording directories
Check user permissions and available
disk space. Check file names and
recording directories
Type
BITE Data
Startup
Data Processing
Data Processing
Input Signal
Input Signal
Data Recording
Data Recording
Data Recording