SC-F2000
4.10.6 Clamp Position Adjustment
REQUIRED TOOL
Scale
PROCEDURE
1.
Open the printer cover.
2.
As shown in
Figure
4-30, adjust the clamps to the center of the cutouts. The
following values are for reference only.
(1) 64mm
(2) 72mm
Cutouts
Figure 4-30. Positioning the Clamp
3.
Release the CR lock.
4.
Move the CR Unit to the full side.
ADJUSTMENT
[Blue]:
Button or menu name on the program screen / [Black]: Button or menu name on the operation panel of the printer
(3) 70mm
CR Related Adjustments
5.
Measure the distances of (4) to (5) shown in
positions if the distances are not the same as those values given in the figure.
(6) 84mm
Figure 4-31. Positioning the Clamp (4) to (6)
Revision C
Figure
4-31, and adjust the clamp
(5) 71mm
(4) 64mm
Confidential
233