Hide thumbs Also See for SC-F2000:
Table of Contents

Advertisement

SC-F2000
3.
Set the gauge unit to the base with the concave section on the gauge unit to the
hole on the base.
4.
Adjust the gauge panel to the front so that you can check the value easily.
5.
Remove the gauge unit by holding its base.
6.
Tighten the screw of the gauge.
Adjust screen to the front.
Screw
Positioning required
Figure 4-78. Setting the gauge unit
ADJUSTMENT
[Blue]:
Button or menu name on the program screen / [Black]: Button or menu name on the operation panel of the printer
Gauge unit
TF Adjustments
7.
Set the gauge unit on the origin position adjuster.
Origin position adjuster
Figure 4-79. Setting the gauge unit on the origin position adjuster
8.
Press the ON/OFF button to turn on the gauge.
9.
Press and hold the SET button to reset the value to "0".
SET button
Figure 4-80. Gauge
Revision C
Gauge unit
ON/OFF button
269