Table 6-12: Altimeter output format – Ulvertech Bathymetric system
6.6.4 Simrad UK90
The Simrad UK90 transmits data at 4800 baud using 8 data bits, 2 stop bits and no parity.
Table 6-13: Altimeter output format – Simrad UK90
Notes:
1. The Simrad UK90 altimeter measures altitude at twice the rate that it measures depth. It there-
fore includes the altitude field twice in each data packet, separated by a space character. Both
altitude fields will contain similar values because it is unlikely the altitude will change signifi-
cantly during the short interval between the two measurements.
2. The contents of these output data fields are set externally and have no effect on operation of
the 440 System.

6.6.5 OSEL Bathymetric System

The OSEL Bathymetric system transmits data at 9600 baud using 8 data bits, 1 stop bit and no parity.
DPN 402196 Issue 4.1
© Teledyne TSS
6 – Operating Procedure