Scalar DLC
dasadmin viewc E301010101
LSCIcoordinate
SCSIcoordinate
Volser
Owner
Attr
Media
UseCount
Ctype
Vtype
Locked
CLMcount
AssociatedDevice
NextLSCIcoordinate E301010102
NextSCSIcoordinate 0
See below an explanation of the return status associated with the viewc command.
Table B-84
Returned Status for Viewc Command Explanation
Display
LSCIcoordinate
10-digit logical coordinate specifying the slot in the library
SCSIcoordinate
SCSI coordinate. Returned only if the target library supports it.
Volser
volser, assigned to given coordinate. This volser can physically not be
present at given coordinate, see Attr for details.
Owner
number of the robot which can access the home coordinate of the named
volser (1 = robot 1, 2 = robot 2, 3 = both robots)
Attr
current status of the slot (attributes).
media
media type, for example, 3590. Refer to
UseCount
number of accesses to the slot (not volser) by the robotic controller
Ctype
type of slot, but not the media type (coordinate in the archive)
Vtype
• U - non-scratch volser
• S - scratch volser
Locked
• DEF/DEFAULT - the volser/drive is not locked
• CLM - the volser or drive is locked by Clean Manager
CLMcount
the number of uses for drive after last cleaning.
9999 means the drive should be cleaned after dismount of current media.
AssociatedDevice • a drive name, if the coordinate is the drive.
• a list of logical ranges which own this coordinate, if the coordinate is EIF.
Next
the next AMU coordinate (if applicable)
LSCIcoordinate
Next
the next SCSI coordinate (if applicable)
SCSIcoordinate
Commands Overview
E301010101
0
1
Empty
3480
0
AMU Dynamic
DEFAULT_L
0
E01,I01
Explanation
Media Types on page
A-9.