Motor Learn - KEB COMBIVERT F5 Operation Manual

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

Motor Learn

4.9. Motor Learn
76
Next, the complete motor data must be learned with the automated learn
function.
The motor characteristics, including the motor's inductance and resistance,
can be learned with the drive's tuning function. The Motor Learn function
can be found under the Tune Parameters group from the Programming menu
(Home > Prog > Tune Parameters > LL01). Begin the procedure by setting:
Motor Tuning LL01 = Start
i
Note: It may be necessary to program the drive outputs accordingly for
proper operation with the controller. Refer to Section 6.13 for setting
the output functions.
Follow the instructions on the LCD screen. The user is instructed to:
1. Disable the brake.
2. If the speed is generated by the controller (Analog or Serial), then set
external speed command to zero.
3. Press and hold inspection (speed + direction + enable inputs) until
completed. Upon successful completion LED 1 and LED 2 will blink green
and red until inspection is dropped.
The process should take 2-5 minutes and will emit a high pitched noise while
the drive measures various motor parameters.
Re-establish proper brake operation wire and return the inspection speed
if changed on the controller.
SETUP OF THE MOTOR LEARN IS NOW COMPLETE!
Scan the QR code to the left to view a walkthrough video of the Motor Tune
Procedure.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents