Customizing Parameter Lists
LC41 will not be accessible in the User or Basic password Levels
LS02 will be accessible in the OEM password level only.
LS01 will be accessible in all password levels: OEM, Adjuster, User, Basic.
LS01 will read-only in the Basic password level
Once the text file for a custom parameter list has been created, it must be
saved as the following: para_dis.txt.
The para_dis.txt file must then be saved to the keypad operator flash memory.
The text file must be transferred via FTP.
To save the custom parameter list text file to flash, OEM password level is
required. From the Programming Menu, the 'File' option (F4) will then be listed.
Under the 'File' list, select 'File Operations' . Under 'File Operations' select
FTP'(F2) When the text file has been transferred to the keypad operator flash
memory, select 'Menu' (F1), then 'Prog' (F1) to return to the Programming Menu.