Serial/Can Hardware Version; Led Indicators - KEB COMBIVERT F5 Operation Manual

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

3.2. Serial/CAN
Hardware Version

3.2.1. LED Indicators

Serial/CAN Hardware Version

Hardware
Use
Pin
1
2
3
4
5
6
7
8
9
The LED indicators are available only on the Serial LCD Operator. The
LEDs are used to indicate operational status. They can be used for trou-
bleshooting and diagnostics. In addition, the function of the LED can be
changed with parameters CH10 - 15.
Off
(Green)
(Orange)
(Red - Blinking) A limit has been
(Red - Solid)
X6C
5
4
3
2
1
9
8
7
6
X6C
CAN | RS 485
Bus Communications Diagnostics
Signal
CAN V+
CAN L
CAN H
RxD A -, RS485
RxD B +, RS485
CAN GND )
Bus Ground
TxD A -, RS485
TxD B +, RS485
LED 1
No operation (noP)
Drive not enabled
Inverter running the
motor
-
reached: Torque,
Current, or Voltage (not
yet implemented)
X6D
5
4
3
2
1
9
8
7
6
X6D
RS 232/485
Signal
TxD, RS232
RxD, RS232
RxD B +, RS485
RxD A -, RS485
VP +5V (10mA)
Bus Ground
TxD B +, RS485
TxD A -, RS485
LED 2
Run mode
Drive is able to run
Stop mode:
Drive is being
programmed or making
calculations;
FTP file transfer mode.
-
Drive is faulted
53