Basic Setup; Inputs/Output Configuration - KEB COMBIVERT F5 Operation Manual

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

Basic Setup

4.3. Basic Setup
4.4. Inputs/Output
Configuration
70
The Basic Setup is where the initial programming must begin. Here, the
application fundamentals are established prior to configuration.
i
Note: In most cases the elevator control manufacturer will make the
adjustments in Basic Set-up but it is good to verify the correct settings.
Prior to configuring the elevator drive, view the controller reference parameter
list (provided by the elevator control manufacturer) to verify the parameters
required for the particular installation of the elevator drive.
The Basic Setup menu can be accessed by: Home > Prog (F3) > Basic Setup.
All these parameters must be adjusted:
US02 - System Units (Imperial/Metric)
US03 - Motor Type (i.e. Induction geared or PM synch gearless)
US04 - Control Type (i.e. Binary, Serial, Analog)
Next, the configuration must be loaded using US05. This step serves to load
the KEB drive with the correct limits and internal settings according to the
application:
US05 - Load Configuration (Write config. to drive)
If loaded successfully, US05 should change from Not configured to Configuration
OK, indicating the drive and operator are synched.
i
If the US04 Control Type or US02 System Units settings are changed after
a configuration has been loaded, a new configuration must be written to the
drive. Writing the new configuration will NOT default all previous settings.
If the US03 Motor Type must be changed after a configuration has been
loaded, a new configuration must be written to the drive and writing the new
configuration WILL default all previous settings.
Then, enter the contract speed of the application, this will set the speed safety
limits internal to the drive:
US06 - Contract Speed
SETUP OF THE BASIC INFO IS NOW COMPLETE!
Next, the inputs and outputs must be configured and assigned functionality
depending on the controller requirements.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents