ENDAT
Drive connection X3A
Female SUBD 15 HD
5
4
3
2
1
10
9
8
7
6
15
14
13
12
11
Encoder Card Part Number: Housing Size ≤ E, 1MF5K8G-PZ43. Housing Size ≥ G 2MF5K8G-PY33
Max. Load capacity depending on Voltage Supply
Max. Load capacity at +5.0V; 300 mA. The specified current is reduced by the current taken from
the second encoder interface X3B interface (see Section 3.3.9).
EnDat Cable
Pre-manufactured EnDat cables offer the best solution against noise and disturbance while at the
same time saving installation time. The cables come in standard lengths of 5m, 10m, 15m, 20m, 25m
and 30m. Specially designed cables are available for applications 40m, 50, 75, 85 and 110m. The
maximum length of KEB cable offered is 110m.
Cable Part Number
00F50C1-40xx xx = length in meters, 10 = 10 meters
For lengths above 30 m a different cable is used.
00F50C1-L0xx xx = length in meters, 40 = 40 meters
Mating Connector
0090912-004U for encoder (solder type), Torin Adaptor 00F50C2-T0P3
Running in Conduit
When this cable must be pulled through metallic conduit, it is necessary to over size the conduit!
Use of a 1 1/2 inch trade size conduit will allow the connectors to pass without removal of the connec-
tors. Cutting the cable, or removal of the connectors or their housings voids the warranty and will result
in problems with electrical noise after the fact.
Circular connector on
EnDat encoder.
4
3
5
2
13
14
6
1
15
12
16
11
8
10
9
EnDat Encoder Interface X3A
Pin No. Signal
3
A-
4
B-
6
CLOCK +
7
CLOCK -
8
A+
9
B+
12
+ 5V
13
COM
14
DATA -
15
DATA +
ONLY when the inverter is switched off and the voltage supply is discon-
nected may the feedback connectors be removed or connected!
Encoder pin-out
COM
10
+5.0V
7
B -
13
B +
12
DATA -
17
DATA +
A -
16
A +
15
Clock -
9
Shield wire tied to housing
Note: Inner pair shields are tied to 0V (com),
pin 13, not earth ground!
Description
Signal input A-
Signal input B-
Synch. signal for serial data
Synch. signal for serial data
Signal input A+ (absolute track for counter and direction detection)
Signal input B+ (absolute track for counter and direction detection)
Supply voltage for encoder
Reference potential for supply voltage
Data channel RS485
Data channel RS485
X3A pin-out channel 1
Wire Color
-40xx
13
0V (com)
White
White
4
B-
Red
Violet
14
DATA - Pink
Pink
15
DATA + Gray
3
A -
Yellow
Brown
7
Clock - Violet
Red
6
Clock + Black
Black
Shield wires tied to housing
which is earth ground.
-L0xx
Gray