Figure; Ac Power Supply Faceplate - Cisco MGX MGX 8800 Hardware Installation Manual

Cisco systems switches installation guide
Hide thumbs Also See for Cisco MGX MGX 8800:
Table of Contents

Advertisement

Cisco MGX 8850 and MGX 8850/B Switches

Figure 1-11

Figure 1-11
1
DC okay LED—Green
2
AC okay LED—Green
The AC power supply requirements for the switch depend on the following criteria:
The number of service modules installed in the switch
Whether the switch is a single AC power cord system or a dual AC power cord system
Use the guidelines in
Table 1-5
Number of Service Modules Installed
Double-Height
1 to 5
6 to 10
11 or more
Cisco MGX 8800/8900 Series Hardware Installation Guide
1-26
shows a close-up of the AC power supply faceplate.

AC Power Supply Faceplate

W
1 2 0 0
3
4
Table 1-5
for the AC power supply requirements.
AC Power Supply Requirements for the MGX 8850 and MGX 8850/B Switch
Single-Height
1 to 10
11 to 20
21 or more
1
2
3
Handle
4
Captive screw
Number of Power Supplies Required per Switch
2 AC power supplies (minimum) for a dual or a single AC
power cord system
4 AC power supplies (minimum) for a dual AC power cord
system (2 on each power cord)
3 AC power supplies (minimum) for a single AC power
cord system
6 AC power supplies for a dual AC power cord system
4 AC power supplies for a single power cord system
Releases 2 - 5.2, Part Number OL-4545-01, Rev. H0, May 2006