Installing the MGX 8950 Switch
Figure 5-47
Connect the AC Power Supply Tray to the MGX 8950 Switch
A system power cable carries –48 VDC current from an AC power tray to the rear of the card cage (see
Figure
plugs into the AC power supply.
If you are using AC power, complete the following steps to connect the AC power supply tray to the
MGX 8950 switch. If you are using DC power, proceed to the
on page
Cisco MGX 8800/8900 Series Hardware Installation Guide
5-80
Fan Power Connections (AC-Powered Node Shown)
DC OUT
AC IN
AC IN
DC OUT
AC IN
AC IN
5-48). One end of the cable plugs into the card cage in the switch and the other end of the cable
5-93.
Chapter 5
Installing the Cisco MGX Switch or Gateway
Upper fan tray cable
Lower fan tray cable
"Connect DC Power to the Switch" section
Releases 2 - 5.2, Part Number OL-4545-01, Rev. H0, May 2006