Installing the MGX 8830 or MGX 8830/B Switch
The CP connection can also be set up through a terminal server, as shown in
Figure 5-79
PXM-UI-S3
back card
C
P
M
P
L
A
N
1
L
A
N
2
E
X
T
C
L
K
1
E
X
T
C
L
K
2
For further information about server management and configuration setup, refer to the appropriate
software configuration guide for your switch and your release.

Connect Power to the MGX 8830 Switch

The section provides the following installation procedures for connecting power to the switch:
Warning
Never install an AC power module and a DC power module in the same chassis. Statement 264
Do not touch the power supply when the power cord is connected. For systems with a power switch,
Warning
line voltages are present within the power supply even when the power switch is off and if the power
cord is connected. For systems without a power switch, line voltages are present within the power
supply when the power cord is connected. Statement 4
Cisco MGX 8800/8900 Series Hardware Installation Guide
5-126
Terminal Server Connection to the Console Port
Terminal server
PXM
UI-S3
Serial cable
Serial, LAN,
or dial-up
connection
Workstation
A
L
A
R
M
"Connect AC Power to the Switch" section on page 5-127
"Connect DC Power to the Switch" section on page 5-127
Chapter 5
Installing the Cisco MGX Switch or Gateway
Figure
Releases 2 - 5.2, Part Number OL-4545-01, Rev. H0, May 2006