Lauda IN 130 T Operation Manual page 128

Integral process thermostats and high-temperature thermostats
Table of Contents

Advertisement

Fig. 76: Example of a temperature graphic
LOG file
128 / 198
The LAUDA device only supports USB sticks which are formatted with the
FAT32 file system. exFAT is not supported.
You can export the following files to the USB stick independently of each
other:
[Temperature graphic]
n
The data record is located in the subdirectory LOGS and contains the
file LOG0.CSV or several .CSV files with ascending numbering in
the case of multiple exports.
[Device status]
n
This data record is located in the subdirectory DEV_DATA and con-
tains the file DEV0.CSV or several .CSV files with ascending
numbering in the case of multiple exports.
For example, the following are stored in this file:
[Device data]
n
This data record is located in the subdirectory DEV_DATA and con-
tains the file DAT0.CSV or several .CSV files with ascending
numbering in the case of multiple exports.
All the existing measured values (temperatures, pressures, voltages, cur-
rents, and so on) are stored in this file as a snapshot of the system.
[Control parameters]
n
This data record is located in the directory LAUDA / USER and contains
the file CTRLPARA.INI. Only such a file can be exported. The file will
be overwritten on re-export.
The file contains all the temperature control parameters as well as the
temperature limits Tih and Til. The file is designed to transfer the settings
of the control parameters from one device to another.
[Analog module config.]
n
[Contact module config.]
These data records can only be exported if an analog module or con-
tact module has been connected to the constant temperature equip-
ment. The configuration is stored in the LAUDA / USER directory in
the ANACFG.INI or CONTCFG.INI file. Only such a file can be
exported in each case. This file will be overwritten on re-export. The file
contains the complete configuration of the connected analog module or
contact module. The file is designed to transfer the configuration from
one constant temperature device to another.
Personnel:
1.
Insert the USB stick in the USB host on the operating unit of the
machine.
2.
Press the Enter key to open the menu.
Integral Process Thermostats and High-Temperature Thermostats
All temperature-time values from the graphics memory of the
device are exported.
Serial numbers
Software version
Hardware version
Running time
Various temperature values
Control parameters
Network settings
Error store
Operating personnel
n