2.4.9
2.4.10
2.4.11
2.4.12
0855855eng 6/08
Ink Line Heater
Parameter Options: On, Off
Access Level: Read–3; Write–3
The Ink Line Heater parameter indicates whether power to the ink
line heater is turned on or off.
Ink Line Current
Parameter Options: On, Off
Access Level: Read–3
The Ink Line Current parameter indicates whether the ink line heater
circuit is complete so that current is flowing through it.
Ink Line Status
Parameter Options: Idle, Heating
Access Level: Read–3
The Ink Line Status parameter indicates whether the ink line heater
is heating or not.
Printhead Voltage
Parameter Options: 115–195 VDC
Access Level: Read–3; Write–4
The Printhead Voltage parameter indicates the power supply
voltage that is required by the printhead to optimally fire the jets.
This voltage is programmed into the printhead when it is
manufactured, and can only be changed by Markem-Imaje service
personnel.
SECTION 4 Diagnostic Tools
4–13
Need help?
Do you have a question about the markem-imaje 5200 and is the answer not in the manual?