MacDon M1170NT5 Operator's Manual page 481

Windrower
Hide thumbs Also See for M1170NT5:
Table of Contents

Advertisement

J1939
J1939
Telltale
SPN
FMI
Check
4344
4
Engine
Check
4344
5
Engine
Stop
4360
0
Engine
Check
4360
2
Engine
Check
4360
3
Engine
Check
4360
4
Engine
Check
4360
15
Engine
Stop
4360
16
Engine
Stop
4363
0
Engine
Check
4363
2
Engine
Check
4363
3
Engine
Check
4363
4
Engine
Stop
4363
16
Engine
215922
REFERENCE
Cummins
Lamp
Fault Code
Aftertreatment 1 Diesel
None
6536
Exhaust Fluid Line Heater
3 State
Aftertreatment 1 Diesel
None
6484
Exhaust Fluid Line Heater
3 State
Aftertreatment 1 SCR
Catalyst Intake Gas
Red
3229
Temperature
Aftertreatment 1 SCR
Catalyst Intake Gas
Amber
3144
Temperature
Aftertreatment 1 SCR
Catalyst Intake Gas
Amber
3142
Temperature
Aftertreatment 1 SCR
Catalyst Intake Gas
Amber
3143
Temperature
Aftertreatment 1 SCR
Catalyst Intake Gas
None
3164
Temperature
Aftertreatment 1 SCR
Catalyst Intake Gas
3231
Red
Temperature
Aftertreatment 1 SCR
Catalyst Outlet Gas
Red
3165
Temperature
Aftertreatment 1 SCR
Catalyst Outlet Gas
Amber
3148
Temperature
Aftertreatment 1 SCR
Catalyst Outlet Gas
None
6569
Temperature
Aftertreatment 1 SCR
Catalyst Outlet Gas
None
6571
Temperature
Aftertreatment 1 SCR
Catalyst Outlet Gas
3235
Red
Temperature
461
J1939_SPN Description
Detail
Aftertreatment Diesel Exhaust
Fluid Line Heater 3 Circuit -
Voltage below normal, or shorted
to low source
Aftertreatment Diesel Exhaust
Fluid Line Heater 3 Circuit -
Current below normal or open
circuit
Aftertreatment 1 SCR Intake
Temperature - Data valid but
above normal operational range -
Most Severe Level
Aftertreatment 1 SCR Intake
Temperature Sensor - Data is
erratic, intermittent, or incorrect
Aftertreatment 1 SCR Intake
Temperature Sensor Circuit -
Voltage above normal, or shorted
to high source
Aftertreatment 1 SCR Intake
Temperature Sensor Circuit -
Voltage below normal, or shorted
to low source
Aftertreatment 1 SCR Intake
Temperature - Data valid but
above normal operating range -
Least Severe
Aftertreatment 1 SCR Intake
Temperature - Data valid but
above normal operating range -
Moderately Severe Level
Aftertreatment 1 SCR Outlet
Temperature - Data valid but
above normal operational range -
Most Severe
Aftertreatment 1 SCR Outlet
Temperature Sensor - Data is
erratic, intermittent, or incorrect
Aftertreatment 1 SCR Outlet
Temperature Sensor Circuit -
Voltage above normal, or shorted
to high source
Aftertreatment 1 SCR Outlet
Temperature Sensor Circuit -
Voltage below normal, or shorted
to low source
Aftertreatment 1 SCR Outlet
Temperature - Data valid but
above normal operating range -
Moderately Severe Level
Revision A

Advertisement

Table of Contents
loading

This manual is also suitable for:

M1170M1240

Table of Contents