Problem
Loose or broken compressor drive belt
Dirty filters
Broken or disconnected electrical wire
Broken or disconnected ground wire
Expansion valve stuck in open or
closed position
Broken refrigerant line
Leak in system
Compressor shaft seal leaking
Clogged screen in receiver-drier;
plugged hose or coil
Symptom: Air conditioning is not producing sufficient cooling (meaning that air temperature in the windrower cab,
measured at the louvered vent, can be maintained at 14°C [57°F] below ambient air temperature)
Compressor clutch slipping
Thermostat defective or improperly
adjusted
Clogged air filters
Heater circuit is open
Insufficient air circulation over
condenser coil; fins clogged with dirt
or insects
Evaporator fins clogged
Refrigerant low
Clogged expansion valve
Clogged receiver-drier
Excessive moisture in system
Air in system
Blower motor sluggish in operation
Symptom: Air conditioning cools intermittently.
Unit icing up due to thermostat
adjusted too low
Unit icing up due to excessive
moisture in system
Unit icing up due to incorrect super-
heat adjustment in the
expansion valve
215922
TROUBLESHOOTING
Solution
Replace drive belt and/or tighten to
specifications.
Clean fresh air and recirculation filters.
Check all terminals for loose
connections; check wiring for
hidden breaks.
Check ground wire to see if loose,
broken, or disconnected.
Contact Dealer.
Contact Dealer.
Contact Dealer.
Contact Dealer.
Contact Dealer.
Remove clutch assembly for service or
replacement.
Replace thermostat.
Remove air filters, and clean or
replace as necessary.
Lower temperature control in cab, and
close valve on engine.
Clean condenser.
Clean evaporator fins (under cab
floor).
Contact Dealer.
Contact Dealer.
Contact Dealer.
Contact Dealer.
Contact Dealer.
Contact Dealer.
Adjust thermostat.
Contact Dealer.
Contact Dealer.
395
Section
Tensioning Air Conditioner Compressor
Belts, page 339
and
Replacing Air
Conditioner Compressor Belts, page
339
5.9.1 Servicing Return Air Filter, page
283
Contact Dealer.
Contact Dealer.
5.9.1 Servicing Return Air Filter, page
283
3.10.3 Climate Controls, page 61
3.10.1 Heater Shut-Off Valve, page 61
Cleaning Left Cooling Module, page
284
Cleaning Air Conditioning Evaporator
Core, page 333
Contact Dealer.
and