Goodrive350A series high-performance multifunction VFD
Function
Name
code
Wait time for restart
P01.22
after power-off
P01.23
Start delay
P01.24
Stop speed delay 0.0–600.0s
Open-loop 0Hz
P01.25
output selection
DEC time for
P01.26
emergency stop
Time of ending
segment of DEC S
curve
P01.27
Time of starting
segment of DEC S
curve
Time of ending
P01.28
segment of DEC S
curve
Short-circuit braking
P01.29
current
P01.30
Hold time of
Description
0: Disable
1: Enable. If the restart condition is met, the
VFD will run automatically after waiting the
time defined by P01.22.
The parameter indicates the wait time before
the automatic running of the VFD that is
re-powered on.
Output frequency
t1
Running
Power off
Setting range: 0.0–3600.0s (valid when
P01.21=1)
After a VFD running command is given, the
VFD is in standby state and restarts with the
delay defined by P01.23 to implement brake
release.
Setting range: 0.0–600.0s
0: Output without voltage
1: Output with voltage
2: Output with the DC braking current for stop
0.0–60.0s
0.0–50.0s
0.0–50.0s
When the VFD starts in direct start mode
(P01.00=0), set P01.30 to a non-zero value to
enter short-circuit braking.
-149-
t1=P01.22
t2=P01.23
t2
t
Running
Power on
Function parameter list
Default
Modify
1.0s
0.0s
0.0s
0
2.0s
0.1s
0.1s
0.0%
0.00s