Commands
Command
Description
LPP <power>
Sets the power going to the light source, in
watts.
Examples
Set the light source to 360W:
(LPP 360)
LSE–Last System Error
Retrieves the last recorded system error.
This command is read only.
Commands
Command
Description
LSE?
Displays the last system error.
LVO–Lens Shift Vertical
Adjusts the vertical lens offset.
Commands
Command
Description
LVO <position>
Adjusts the vertical location of the lens to
the specified position. This position is
persistent across AC cycles. (Saved value)
Examples
Move the lens to position 500 on the vertical axis:
(LVO 500)
GS Series Serial API Commands Technical Reference
020-000814-01 Rev. 1 (06-2015)
Values
280 to 370
Values
1 = The light source did not engage after five attempts
3 = The light source went out unexpectedly
4 = Fan failure
5 = Over temperature
Values
postion = A numerical value