5.3 IP filter Settings
The IP filter setting limits which client PCs are able to link to the PDS-220FX series
module via specific IP addresses. When one or more IP addresses are set in the filter
table, only client PCs where the IP address is included in the range listed of the filter table
will be able to connect to the PDS-220Fx series module. Any requests from other PCs will
be rejected
Set IP1 only: Set a single IP address, the IP address entered in the "IP1" and
"IP2/MASK" text fields will be the same, as the image below shows. Only clients
who's IP address is included in the filter table are able to connect to the PDS-220Fx
series module.
Set IP1 + IP2: Set a range of IP address as a starting and ending point. The initial IP
address must be entered in the "IP1" text field and final IP address must be entered
in the "IP2/MASK" text field, as the image below shows.
This allows clients who's IP address is included in the range of 10.0.9.5 to 10.0.9.55
are able to connect to the PDS-220Fx series module.
PDS-220Fx Series User Manual (V1.2, Apr. 2015)
33