ICP DAS USA PDS-220F Series User Manual page 31

Hide thumbs Also See for PDS-220F Series:
Table of Contents

Advertisement

ГК Атлант Инжиниринг – официальный представитель в РФ и СНГ
+7(495)109-02-08 sales@bbrc.ru www.bbrc.ru
UDP Search: 0 = disabled, 1 = always enabled.
2 = enable the UDP Search function until another client is connected. (Default = 2)
By keeping the UDP search setting as 2, the PDS-220Fx loading will be reduced. The
VxComm Utility will not be able to search for this module until this module's clients are all
disconnected.
Command Port:
The default Command Port is 10000.
Web Server
Telnet Server
0 = disabled, 1 = enabled
Ping Gateway at start: 0 = disabled, 1 = enabled.
If the setting is 1 (enabled), the PDS-220Fx series module will send a ping packet to the
gateway during the power-on stage. It is used to inform the gateway that a PDS-220Fx
(itself) has joined the network.
TCP ACK Delay (ms), default = 50.
PDS-220Fx does not want to send an empty ACK followed by a TCP data packet 1ms
later, every time. So it delays a little (TCP ACK Delay), and then can combine the ACK
and data packet into one. This efficiency reduces the number of packets and reduces
network loadings.
Broadcast
1 = receive UDP broadcast packets
0 = reject UDP broadcast packets
Connection WDT timeout (ms): default = 0 (disabled), min. = 10000.
If the PDS-220Fx series module does not receive any data from a client PC within the
period of the "Connection WDT timeout", the module will close the connection to the client.
PDS-220Fx Series User Manual (V1.2, Apr. 2015)
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pds-220ftPds-220fcPds-220fcsPds-220fcs-60

Table of Contents