Step 10: Execute ping 192.168.255.1 –t using a run command as follows:
!
Note:
 192.168.255.1 is the default IP of the PDS-220Fx series module. The IP address can
be changed using the instructions in step 7.
 If the PDS-220Fx cannot be successfully pinged from the PC, refer to step 7 to change
the configuration of the PDS-220Fx series module. (The mask and gateway addresses
of PDS-220Fx series module and the PC should make the network definition.)
 The MAC address of the PDS-220Fx series module should be unique on the same
network. Refer to step 7 for details of how to change the MAC address of the PDS-
220Fx series module.
 Each PDS-220Fx MAC address is unique in the default shipping.
In general, if the host PC can ping the PDS-220Fx series module smoothly and
continuously, all other software and drivers for the PDS-220Fx series module will operate
correctly. Therefore, users should ensure that the development PC is able to ping the
PDS-220Fx series module smoothly before any further testing is carried out.
PDS-220Fx Series User Manual (V1.2, Apr. 2015)
Execute Ping 192.168.255.1
on the PC client.
The ping results should be
smooth and continuous
79