SocketTimeout (ms)

7.3.7
Description: This command is used to query or set the SocketTimeout parameter.
If the SocketTimeout is greater than zero, and the PDS-220Fx does not receive any data
from a client PC for longer than the SocketTimeout period, the PDS-220Fx will close the
socket connection between itself and the client PC.
Effect: Immediate
Command
SocketTimeout
SocketTimeout
Example:
M
7.3.8
Description: This command is used to query or set the echo mode.
Effect: Immediate
Command
Arguments
M
M
= 0
M
= 1
Example:
PDS-220Fx Series User Manual (V1.2, Apr. 2015)
Arguments
Description
Queries the SocketTimeout settings.
Sets the SocketTimeout. (Unit : ms)
= nnnnn
default = 0 (disable), min = 10000
Description
Queries the echo mode settings.
Sets the multi-echo mode to enable.
When set to multi-echo mode, the PDS-220Fx echoes data from a
device to all clients that are connected.
Sets the single-echo mode to enable.
When set to single-echo mode, the PDS-220Fx echoes data from a
device to the client that requested the service.