Network WDT timeout (ms): 0 = disabled, min. = 30000.
If the PDS-220Fx series module does not receive any data from any of the clients within
the period of the "Network WDT timeout", the module will reboot itself. The default setting
should be 300000ms (= 300 seconds).
This setting is the same as "SystemTimeout" setting (unit: ms) on Console/Telnet
command, and is the same as "/STxxx" in command line parameter (unit: seconds).
When user uses "config=RESET" Console/Telnet command to clear the EEPROM, the
"Network WDT timeout" (SystemTimeout, /ST) setting will also be cleared to 0.
Users have to configure this setting again by "SystemTimeout" Console/Telnet command.
Master IP: default = empty (disabled).
If the Master IP is set, only the client using Master IP can change the COM Port
configuration. It is to prevent the COM Port configuration changed by other clients.
After setting the new configuration, click the "Set TCP/IP" button to save the new settings
to the PDS-220Fx series module. If the "Reset System" option is checked, the PDS-220Fx
series module will reboot itself after the saving operation is complete, otherwise the
original settings will still be valid until the next power-on.
PDS-220Fx Series User Manual (V1.2, Apr. 2015)
32