5.3. IP filter setting

The IP filter setting limits which client PCs are able to link to the PDS series module
via specific IP addresses. When one or more IP addresses are set in the filter table, only
client PCs where the IP address is included in the range listed of the filter table will be
able to connect to the PDS series module. Any requests from other PCs will be rejected
Set IP1 only: only clients who's IP address is included in the filter table are able to
connect to the PDS series module.
Set IP1 + IP2: set a range of IP address as a starting and ending point. The setting
allows clients who's IP address is included in the range are able to connect to the PDS
series module.
Set IP1+Mask: set the IP filter range as:
Only clients who's IP address is included in the range are able to connect to the PDS
series module. For instance:
IP1 = 10.0.9.5, mask = 255.255.255.0
IP1 & MASK = 10.0.9.0, ~mask = 0.0.0.255
This allows clients who's IP address is included in the range of 10.0.9.0 ~ 10.0.9.255
are able to connect to the PDS series module.
(IP1 & Mask) + 0 ~ (IP1 & Mask) + (~Mask).