SOCKET

7.3.3
Description: This command lists the status of all sockets (Listen/Not Used Yet) together
with the type of each socket (TCP Server: Port No./UDP/Unused)
If stat = 1, the socket is used. If stat = 0, the socket is not yet used.
Take Effect: Immediately
Command
socket
Example:
PDS-220Fx Series User Manual (V1.2, Apr. 2015)
Argument
Description
Lists the status of all sockets.