Command Syntax
Description
Default Value
Success
Error
Command Syntax
Description
Default Value
Success
Error
Command Syntax
Description
Default Value
Success
Error
Command Syntax
Description
Default Value
Success
Error
Multi-Tech Systems, Inc. MultiConnect Serial-to-Serial Adapter User Guide (S000354A)
set ppp <interface> local-ip-addr <ipaddr> mask <ipmask>
During IPCP negotiations, the configured IP address is sent for the local
interface. In the case where the peer is requested to provide the IP
address, it can be configured as 0.0.0.0
0.0.0.0
255.255.255.0
OK
1. Too few arguments
Possible arguments are IP Address and Mask
2. Invalid IP address/Mask
Invalid argument
set ppp <interface> password <password >
Sets the password that remote peers will use for authentication.
Ipmodule
OK
1. Password Length
Password should have minimum of 8 characters
set ppp <interface> remote-ip-addr <ipaddr> mask <ipmask>
During IPCP negotiations, this configured IP address is sent for the remote
interface. In the case of the peer being requested to provide the IP address,
it can be configured as 0.0.0.0
0.0.0.0
255.255.255.0
OK
1. Too few arguments
Possible arguments are IP Address and Mask
2. Invalid IP address/Mask
Invalid argument
set ppp <interface> username <username>
Sets the user name that the remote peer will use for authentication.
Ipmodule
OK
1. Too few arguments
Possible value(s) are valid user name
Chapter 4 – Command Line Interface (CLI)
PPP Commands – Setup