BATTERY SERVICE

BATTERY SPECIFICATIONS

Battery PN 4014043 / 4014132-P
Type
Polaris Maintenance Free
Voltage
12 Vdc
Nominal Capacity
32 AH
@ 20 HR Rate
Deka - 450
CCA - 2013 Models
Johnson Controls - 575
CCA - 2014 Models
Johnson Controls - 575
Nominal Open
12.8 Vdc or more.
Circuit Voltage
Recommended
1.8A @ 5-10 HR or 6.0A @ 1
Charging Rate
HR
NOTE
Never attempt to open the battery.

GENERAL BATTERY INFORMATION

WARNING
CALIFORNIA PROPOSITION 65 WARNING:Batteries,
battery posts, terminals and related accessories contain
lead and lead compounds, and other chemicals known
to the State of California to cause cancer and birth
defects or other reproductive harm. WASH HANDS
AFTER HANDLING.
WARNING
Battery electrolyte is poisonous. It contains acid!
Serious burns can result from contact with the skin,
eyes, or clothing.ANTIDOTE:External: Flush with water.
Internal: Drink large quantities of water or milk. Follow
with milk of magnesia, beaten egg, or vegetable oil. Call
a physician immediately.Eyes: Flush with water for 15
minutes and get prompt medical attention.Batteries
produce explosive gases. Keep sparks, flame,
cigarettes, etc. away. Ventilate when charging or using
in closed space. Always shield eyes when working near
batteries.Keep out of reach of children.
1. Check battery voltage with a volt/ohm meter. A fully
charged battery should be 12.8 V or higher.
2. If the voltage is below 12.6 V, the battery will need to
be recharged (see "Charging Procedure").
To service a Maintenance Free battery:
9924880 Rev 2- 1/10/2014 - 2013 / 2014 RANGER XP 900 - 2014 RANGER XP 900 / CREW 900 Service Manual
© Copyright Polaris Sales Inc.
3. Remove battery from the vehicle (see Chapter 2).
4. Test battery with a voltage meter or load tester to
determine battery condition. This will determine the
length of time required to charge the battery to full
capacity. Refer to OCV table (see "OCV - Open
Circuit Voltage Test").
5. Charge the battery as recommended (see "Charging
Procedure").

BATTERY TERMINAL BLOCK

The terminal block (A) is located under the hood near the
radiator pressure cap. The terminal block provides easy
hookup for accessories.
TORQUE
Terminal Block Nuts:20-25 in-lbs (2.3-2.8 Nm)
ELECTRICAL
10
10.33

Advertisement