7. Remove the thermostat cover (B), seal (D) and
thermostat (E) from the engine.
NOTE
Thermostat has a pop-off relief to allow the bypass
system to operate until thermostat opens.
8. Clean thermostat mating surfaces on the engine and
thermostat cover.
9. Install a new thermostat and seal into the cover and
install the cover onto engine.
10. Install the thermostat cover bolts and torque the bolts
to specification.
TORQUE
Thermostat Cover Bolts:89 ± 9 in-lbs (10 ± 1 Nm)
11. Install coolant hose back on the thermostat cover
and securely tighten the hose clamp.
12. Fill cooling system and proceed to "Cooling System
Bleeding Procedure" provided in this chapter.
9924880 Rev 2- 1/10/2014 - 2013 / 2014 RANGER XP 900 - 2014 RANGER XP 900 / CREW 900 Service Manual