14.7
Diaphragm rupture sensor
Contact (standard)
14.8
Relay
14.9
Sound pressure level
Sound pressure level
Data
Switch on peak current, (for approx. 100
ms)
Electrical data at 230 V
Data
Switch on peak current, (for approx. 100
ms)
Fuses
Fuse
Value
Fuse, internal
3.15 AT - (1.5 kA)
Only use the original fuses from ProMinent! It is not sufficient
to use a fuse with the above fuse rating.
Contact loading, max.
at voltage
Maximum current
30 V DC
1 A
The contact is an opener.
The contact is an potential-free.
For safety reasons we recommend connecting to a pro‐
–
tective low voltage, e.g. in accordance with EN 60335-1
(SELV ).
The cable can be poled as required.
–
The technical data for the relay are contained in the chapter
"Installation, electrical".
Sound pressure level LpA < 70 dB in accordance with EN ISO
20361:2010-10
at maximum stroke length, maximum stroke rate, maximum back pressure
(water)
Technical data
Value Unit
4 A
Value Unit
8 A
Part no.
732414
83