Dosing Precision; Reproducibility; Viscosity; Weight - ProMinent Hydro/4 Operating Instructions Manual

Metering pump
Table of Contents

Advertisement

Type
Minimum pump capacity at maximum back pres‐
sure
bar
70465
6
70670
6
70890
6
71230
6
13.2

Dosing precision

13.2.1

Reproducibility

13.3

Viscosity

13.4

Weight

psi
l/h
gph
87
560
147.9
87
805
212.7
87
1070
282.7
87
1450
383.0
* Maximum back pressure for TTT, PPT and PCT material versions: 10
bar!
All figures refer to water at 20 °C.
Priming lift / priming pressure (dry) determined for empty suction line and
empty liquid end and as well as clean and moistened valves (the figures
are lower with valve springs).
The suction lift / suction pressure applies to filled suction lines and filled
liquid end - when installed correctly.
Data
Reproducibility
* for measurements taken under constant conditions, minimum 10 %
stroke rate and water at 20 °C - when installed correctly and with a back
pressure of at least 1.5 bar
The liquid ends are suitable for the following viscosity ranges:
Design
no valve springs
with valve springs
For pumps with a standard motor.
Maximum
Suction lift
Permis‐
stroke rate
sible pri‐
ming pres‐
sure,
suction
side
Strokes/
m WS
bar
min
86
3 m
1 bar
124
3 m
1 bar
164
3 m
1 bar
225
3 m
1 bar
Range
0 ... 200
200 ... 500
Technical data
Connector
size
G-DN
G2 1/4-DN
40
G2 1/4-DN
40
G2 1/4-DN
40
G2 1/4-DN
40
Value Unit
±1 % *
Unit
mPas
mPas
61